1).载流量不应小于负荷计算电流;
1). Should not be less than the load calculation of current carrying capacity;
2).满足机械强度的要求;
2). To meet the requirement of mechanical strength;
3).自配电变压器的低压母线至卢重机电动机端子的电压损失,在尖峰电流时,不宜超过额定电压的15%。
3). The voltage loss from low voltage distribution transformer to Lu heavy machinery motor terminal, the peak current, should not exceed 15% of the rated voltage.
2.少起重机供电线路的电压损失,可根据具体情况采取下列措施:
2 little crane voltage loss of power supply line, the following measures may be adopted according to the specific situation:
1).电源线尽量接至天车滑线的中部;
1). The central power line as far as possible to crane slide wire;
2).采用绝缘式安全滑触线;
2). The insulation safety sliding contact line;
3).适当增大滑触线截面或增设辅助导线;
3). Increasing the sliding contact line section or adding the auxiliary conductors;
4).增加滑触线供电点或分段供电;
4). To increase the sliding contact line power supply or sectional power supply point;
5).增大电源线或软电缆截面。
5). Increasing the power line or cable section.
3.绝缘式安全滑触线装设膨胀补偿装置的要求,应根据产品技术参数确定。
3 insulation type safety sliding contact line expansion compensation device requirements, should be determined according to the technical parameters of the product.