上海沪震生物科技有限公司作者
牛牛天天人人综合影院 血管生成素样蛋白4(ANGPTL4)检测试剂盒说明书
资料类型 | doc文件 | 资料大小 | 20992 |
下载次数 | 164 | 资料图片 | 【点击查看】 |
上 传 人 | 上海沪震生物科技有限公司 | 需要积分 | 0 |
关 键 词 | 血管生成素样蛋白4(ANGPTL4)检测试剂盒,血管生成素样蛋白4(ANGPTL4)检测试剂盒,血管 |
- 【资料简介】
-
血管生成素样蛋白4(ANGPTL4)检测试剂盒
适用生物 Homo sapiens (Human,人)
血管生成素样蛋白4(ANGPTL4)检测试剂盒检测范围 0.781-50ng/mL 灵敏度 0.29ng/mL
样本类型 Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.
实验时长 4.5h 实验方法 双抗夹心法 血管生成素样蛋白4(ANGPTL4)检测试剂盒规格 96T
血管生成素样蛋白4(ANGPTL4)检测试剂盒 ELISA Kit for Angiopoietin Like Protein 4 (ANGPTL4)
FOR IN VITRO AND RESEARCH USE ONLY, NOT FOR USE IN CLINICAL DIAGNOSTIC PROCEDURES!Organism species Homo sapiens (Human)
Product No. SEB019Hu
Sample type Serum, plasma, tissue homogenates, cell lysates, cell culture supernates and other biological fluids.
Format 96-well strip plate
Assay length 4.5 hours
Detection range 0.781-50ng/mL The standard curve concentrations used for the ELISA’s were 50ng/mL, 25ng/mL, 12.5ng/mL, 6.25ng/mL, 3.125ng/mL, 1.563ng/mL, 0.781ng/mL
Sensitivity The minimum detectable dose of this kit is typically less than 0.29ng/mL.Specificity
This assay has high sensitivity and excellent specificity for detection of Angiopoietin Like Protein 4 (ANGPTL4).
No significant cross-reactivity or interference between Angiopoietin Like Protein 4 (ANGPTL4) and analogues was observed.
Recovery
Matrices listed below were spiked with certain level of recombinant Angiopoietin Like Protein 4 (ANGPTL4) and the recovery rates were calculated by comparing the measured value to the expected amount of Angiopoietin Like Protein 4 (ANGPTL4) in samples.
Matrix Recovery range (%) Average(%)
serum(n=5) 80-98 87
EDTA plasma(n=5) 96-103 99
heparin plasma(n=5) 81-95 89Precision
Intra-assay Precision (Precision within an assay): 3 samples with low, middle and high level Angiopoietin Like Protein 4 (ANGPTL4) were tested 20 times on one plate, respectively.
Inter-assay Precision (Precision between assays): 3 samples with low, middle and high level Angiopoietin Like Protein 4 (ANGPTL4) were tested on 3 different plates, 8 replicates in each plate.
CV(%) = SD/meanX100
Intra-Assay: CV<10%
Inter-Assay: CV<12%
Linearity
The linearity of the kit was assayed by testing samples spiked with appropriate concentration of Angiopoietin Like Protein 4 (ANGPTL4) and their serial dilutions. The results were demonstrated by the percentage of calculated concentration to the expected.
Sample 1:2 1:4 1:8 1:16
serum(n=5) 85-96% 79-92% 78-104% 91-99%
EDTA plasma(n=5) 91-98% 95-104% 94-104% 85-102%
heparin plasma(n=5) 94-101% 96-104% 83-93% 79-89%Stability
The stability of kit is determined by the loss rate of activity. The loss rate of this kit is less than 5% within the expiration date under appropriate storage condition.
To minimize extra influence on the performance, operation procedures and lab conditions, especially room temperature, air humidity, incubator temperature should be strictly controlled. It is also strongly suggested that the whole assay is performed by the same operator from the beginning to the end.
Reagents and materials providedReagents Quantity Reagents Quantity
Pre-coated, ready to use 96-well strip plate 1 Plate sealer for 96 wells 4
Standard 2 Standard Diluent 1×20mL
Detection Reagent A 1×120μL Assay Diluent A 1×12mL
Detection Reagent B 1×120μL Assay Diluent B 1×12mL
TMB Substrate 1×9mL Stop Solution 1×6mL
Wash Buffer (30 × concentrate) 1×20mL Instruction manual 1Assay procedure summary
1. Prepare all reagents, samples and standards;
2. Add 100μL standard or sample to each well. Incubate 2 hours at 37oC;
3. Aspirate and add 100μL prepared Detection Reagent A. Incubate 1 hour at 37oC;
4. Aspirate and wash 3 times;
5. Add 100μL prepared Detection Reagent B. Incubate 30 minutes at 37oC;
6. Aspirate and wash 5 times;
7. Add 90μL Substrate Solution. Incubate 15-25 minutes at 37oC;
8. Add 50μL Stop Solution. Read at 450nm immediay.
Test principle
The test principle applied in this kit is Sandwich enzyme immunoassay. The microtiter plate provided in this kit has been pre-coated with an antibody specific to Angiopoietin Like Protein 4 (ANGPTL4). Standards or samples are then added to the appropriate microtiter plate wells with a biotin-conjugated antibody specific to Angiopoietin Like Protein 4 (ANGPTL4). Next, Avidin conjugated to Horseradish Peroxidase (HRP) is added to each microplate well and incubated. After TMB substrate solution is added, only those wells that contain Angiopoietin Like Protein 4 (ANGPTL4), biotin-conjugated antibody and enzyme-conjugated Avidin will exhibit a change in color. The enzyme-substrate reaction is terminated by the addition of sulphuric acid solution and the color change is measured spectrophotometrically at a wavelength of 450nm ± 10nm. The concentration of Angiopoietin Like Protein 4 (ANGPTL4) in the samples is then determined by comparing the O.D. of the samples to the standard curve.
2024世环会【工业节能与环保展】

div6月3日,2024世环会【工业节能与环保展】于上海丨国家会展中[详细]
- 第4届中国环博会成都展
- 2023世环会【工业节能与环保展】
- 浙江永发机电有限公司
- 改善水生态,循环水资源——杭州天创环境
上一篇:elisa实验用的试剂
- 凡本网注明"来源:环保在线"的所有作品,版权均属于环保在线,转载请必须注明环保在线,http://www.gsrxyx.com。违反者本网将追究相关法律责任。
- 企业发布的公司新闻、技术文章、资料下载等内容,如涉及侵权、违规遭投诉的,一律由发布企业自行承担责任,本网有权删除内容并追溯责任。
- 本网转载并注明自其它来源的作品,目的在于传递更多信息,并不代表本网赞同其观点或证实其内容的真实性,不承担此类作品侵权行为的直接责任及连带责任。其他媒体、网站或个人从本网转载时,必须保留本网注明的作品来源,并自负版权等法律责任。
- 如涉及作品内容、版权等问题,请在作品发表之日起一周内与本网联系,否则视为放弃相关权利。